Air Flow in the settings described in figures 6 and 7
are illustrated in Figure 8.
These cleaners use a single 12 volt, wedge base
Headlight part # 27313101.
To replace the bulb, the carpet height adjuster (B) has
to be taken off then 4 screws (A) have to be removed
from the top of the hood. Fig. 9.
One Flat Belt #38528027 is used to drive the
agitator. To get to the belt, four screws must be
removed from the bottom plate. Fig. 10.
NOTE: THE AGITATOR ROTATES AS LONG AS
THE CLEANER IS TURNED ON.
Fig. 9
Refer to the Hoover Service Manual for repair
procedures and the Microfiche Parts Catalog, light
brown header, for spare parts.
Warranty - 56115015 - Full One Year
(Domestic use)